Ultrasonic Flow Meter
- Home
- Ultrasonic Flow Meter
Ultrasonic Flow Meter
Ultrasonic flowmeters use sound waves to determine the velocity of a fluid flowing in a pipe. At no flow conditions, the frequencies of an ultrasonic wave transmitted into a pipe and its reflections from the fluid are the same. Under flowing conditions, the frequency of the reflected wave is different due to the Doppler effect. When the fluid moves faster, the frequency shift increases linearly. The transmitter processes signals from the transmitted wave and its reflections to determine the flow rate. Transit time ultrasonic flowmeters send and receive ultrasonic waves between transducers in both the upstream and downstream directions in the pipe. At no flow conditions, it takes the same time to travel upstream and downstream between the transducers. Under flowing conditions, the upstream wave will travel slower and take more time than the (faster) downstream wave. When the fluid moves faster, the difference between the upstream and downstream times increases. The transmitter processes upstream and downstream times to determine the flow rate.
Key Features
Industrial Applications
Technical Specifications
| Line Size (mm) | Flow Range (M³/Hr) | |
|---|---|---|
| Min. Flow | Max. Flow | |
| 15 | 0.06 | 6.4 |
| 20 | 0.11 | 11 |
| 25 | 0.17 | 17.7 |
| 32 | 2.9 | 29 |
| 40 | 0.45 | 45 |
| 50 | 0.7 | 70.7 |
| 65 | 1.2 | 119.5 |
| 80 | 1.8 | 181 |
| 100 | 2.8 | 282.7 |
| 125 | 4.4 | 441.8 |
| 150 | 6.3 | 636.2 |
| 200 | 11.3 | 1131 |
Technical Specifications
| Parameter | Details |
|---|---|
| Measurement Principle | Ultrasonic Transit-Time / Doppler |
| Flow Range | 0.1 to 10 m/s |
| Accuracy | ±1.5% of Reading |
| Repeatability | ±0.2% |
| Pipe Size Range | DN15 to DN6000 |
| Fluid Type | Clean Liquids / Slurries (depending on model) |
| Temperature Range | -40°C to 150°C |
| Pressure Range | Up to 100 bar |
| Power Supply | 24V DC / 230V AC |
| Output Signals | 4-20 mA, Pulse, Modbus, HART |
| Protection Class | IP65 / IP68 |
| Installation Type | Clamp-on / Inline |
| Display | LCD with Backlight |
| Communication | RS485 / Ethernet (Optional) |
Transducer Type
| Flow Transducer | Model | Measuring Range | Temperature |
|---|---|---|---|
| Clamp On |
TS - 2 (Small) / TM - 1 (Medium) / TL - 1 (Large) |
DN25 – 100 / DN50 – 700 / DN300 – 6000 |
−30 – 90 Degree C |
| High Temp. Clamp On |
TS - 2 – HT (Small) / TM – 1 – HT (Medium) / TL – 1 – HT (Large) |
DN25 – 100 / DN50 – 700 / DN300 – 6000 |
−30 – 160 Degree C |
| Insertion |
TC – 1 (Standard) / TC – 2 (Extended) / TP – 1 (Parallel) |
DN50 – 6000 / DN50 – 6000 / DN200 – 6000 |
−30 – 160 Degree C |
| Inline | Standard | DN15 - 1000 | −30 – 160 Degree C |
Ordering Information_SS FLOW_UFM_Line Size
| Parameter | Specification |
|---|---|
| Meter Type | Portable / Insertion |
| Output |
Flange 4 to 20 mA RS485 4-20 mA + HART Pulse Relay |
| Sensor Type |
S – 25 to 100 M – 50 to 700 L – 300 to 6000 |
| Protection | IP65 / IP67 |
| Temperature |
-30 to 90°C -30 to 150°C |
| Enclosure Type | Flame Proof / Non Flame Proof |
| Power Supply | Battery Operated / 24V DC / 230V AC |