Capacitance Level Transmitter
- Home
- Capacitance Level Transmitter
Capacitance Level Transmitter
Capacitance level transmitter is used in level sensing applications of variety of Liquids. It’s available for non conductive as well as conductive liquids. It is offered with PTFE sleeve for better insulation & to withstand high temperature. In conductive tanks the insulated probe acts as one electrode & the tank wall as another lectrode, any change in liquid level the dielectric value will change thereby changing the capacitance value proportional to the liquid level. In case of non conductive media applications / non conductive tanks, a reference probe is provided as ground electrode. The output is 4-20mA, 4 wire connection for Isolated supply & 3 wire for non isolated supply. The tank empty ( 4mA) & full (20mA) calibration is through easy field calibration button in case of 4 wire & 3 wire. Rigid probe is offered for tank depth upto 3 mtr & Flexible probe upto 30 mtr. Rigid Probe with Grounding tube is suitable for Fuel Level measurement. It is available with different mounting arrangement to suit customer requirement.
Key Features
• Easy calibration on site
• IP66 ingress protection
Industrial Applications
Technical Specifications
| Parameter | Specification |
|---|---|
| Type | Capacitance Level Transmitter |
| Supply | 24V DC, 230V AC |
| Output | 4–20 mA, RS485, Relay |
| Permissible Load | 500 Ω |
| Measurement Range | 200 MM to 2000 MM in Rigid Probe; Up to 30000 MM in Flexible Probe for other Liquids |
| Max Pressure | Up to 5 KG/CM³ |
| Temperature | 25°C to 120°C |
| Enclosure | Die-cast Aluminium, Weatherproof / Flameproof, IP66 |
| Resolution | 0.5 MM |
| Accuracy | ±0.5–1% of Full Scale |
| Process Connection | 1" / 1½" BSP / NPT / Flanges (Specify) |
| Cable Entry | ½" or ¾" ET / NPT (Specify) |
Ordering Information_SS FLOW _ CPLT
| Parameter | Specification |
|---|---|
| Type | Capacitance Level Transmitter |
| Material | 1. SS304 / 2. SS316 / 3. Other |
| Power Supply | 1. 24V DC / 2. 230V AC |
| Output | 1. 4–20 mA / 2. RS485 / 3. Relay |
| Permissible Load | 500 Ω |
| Measurement Range | 200 MM to 2000 MM in Rigid Probe; Up to 30000 MM in Flexible Probe for other liquids |
| Max Pressure | Up to 5 KG/CM³ |
| Temperature | 1. 120°C / 2. Above 120°C |
| Enclosure | Die-cast Aluminium, Weatherproof / Flameproof |
| Protection | 1. IP66 / 2. Other |
| Resolution | 0.5 MM |
| Accuracy | ±0.5–1% of Full Scale |
| Process Connection | 1. Thread / 2. Flange |
| Cable Entry | ½" or ¾" ET / NPT (Specify) |